简化您的工作流程:搜索 miniwebtool。
添加插件
你可能也用得上
电容器计算器kVA计算器功率因数计算器
主页 > 杂项 > 电子工具 > Capacitor Bank Sizing Calculator
 

Capacitor Bank Sizing Calculator

Find the capacitor bank kVAR needed to correct your power factor to a target value. Enter kW, kVA, or measured volts and amps, and get the required kVAR, a matching standard capacitor bank built from real off-the-shelf steps, the per-phase capacitance in microfarads for both delta and wye connections, capacitor current with NEC 460.8 conductor and fuse sizing, released transformer capacity, and an animated power triangle showing the correction.

Capacitor Bank Sizing Calculator
Quick examples — click to fill the form, then press Calculate:
kW
V
Line-to-line voltage, e.g. 480, 415, 400 or 208
From the utility bill or meter. 0.75 or 75 both work.
0.95 is the usual utility threshold.

Embed Capacitor Bank Sizing Calculator Widget

Capacitor Bank Sizing Calculator

The Capacitor Bank Sizing Calculator tells you exactly how many kVAR of power factor correction capacitors a load needs to move from its present power factor to a target such as 0.95. Enter the load as kW, as kVA, or as a clamp-meter reading in volts and amps, and the calculator returns the required kVAR, a bank you can actually buy built from standard capacitor ratings, the capacitance in microfarads for both delta and wye connections, the capacitor current with conductor and fuse sizing, and the transformer capacity the correction releases.

What is a capacitor bank and why size it?

Motors, transformers, welders and fluorescent ballasts are inductive: they draw a magnetising current that lags the voltage. That current does no useful work, but it still flows through every cable, breaker and transformer between the load and the utility. A capacitor bank installed near the load supplies that magnetising current locally, so the supply only has to deliver the real power. The result is a higher power factor, lower line current, less voltage drop, fewer losses, and — usually the reason the project gets funded — no more power factor penalty on the electricity bill.

Sizing matters in both directions. Too little kVAR and the penalty stays. Too much and the system overcorrects into a leading power factor at light load, which raises voltage, can upset generators and standby sets, and is penalised by many tariffs exactly like a lagging power factor.

Capacitor bank sizing formula

The whole calculation rests on one idea: capacitors change the reactive power \(Q\) and leave the real power \(P\) alone. The required kVAR is simply the difference between the reactive power you have and the reactive power you want.

Required capacitor kVAR
$$Q_C = P \times \left( \tan(\cos^{-1}\!PF_1) - \tan(\cos^{-1}\!PF_2) \right)$$
Real power from a kVA or ammeter reading
$$P = S \times PF_1 \qquad S_{3\phi} = \frac{\sqrt{3} \times V \times I}{1000} \qquad S_{1\phi} = \frac{V \times I}{1000}$$
Capacitance for a given kVAR
$$C_{\Delta} = \frac{Q_C / 3}{2\pi f V_{LL}^2} \qquad C_{Y} = 3 \times C_{\Delta} = \frac{Q_C}{2\pi f V_{LL}^2}$$

Where \(PF_1\) is the present power factor, \(PF_2\) the target, \(f\) the supply frequency in hertz, and \(V_{LL}\) the line-to-line voltage. The bracketed term is the familiar kVAR multiplier found in correction tables — it is what the table below lists.

Worked example

A 480 V three-phase plant draws 100 kW at a power factor of 0.75 and the utility wants 0.95. \(\tan(\cos^{-1}0.75) = 0.8819\) and \(\tan(\cos^{-1}0.95) = 0.3287\), so the multiplier is 0.5532 and the bank needs \(100 \times 0.5532 = 55.3\) kVAR. The nearest buildable bank is 60 kVAR (a 50 plus a 10), the apparent power falls from 133.3 kVA to 105.3 kVA, and the line current drops from 160 A to 127 A — 28 kVA of transformer capacity handed back without touching the transformer.

kVAR multiplier table

Multiply your load in kW by the factor where your present power factor meets your target.

Present PFTarget 0.90Target 0.95Target 0.98Target 1.00
0.600.8491.0051.1301.333
0.650.6850.8400.9661.169
0.700.5360.6920.8171.020
0.750.3980.5530.6790.882
0.800.2660.4210.5470.750
0.850.1350.2910.4170.620
0.900.1560.2810.484
0.920.0970.2230.426
0.950.1260.329

Notice how the last column grows. Going from 0.95 to 1.00 on a 100 kW load costs another 32.9 kVAR — about the same again as correcting 0.90 to 0.95 twice over. That is why almost nobody corrects to unity.

Delta or wye — which connection?

△ Delta (mesh)

Each cell sits across the full line-to-line voltage, so it produces three times the reactive power per microfarad. Needs the least capacitance and is the standard choice for low-voltage banks below 600 V. Every cell must be rated for the full line voltage.

Y Wye (star)

Each cell sees only \(V/\sqrt{3}\), so it needs three times the capacitance for the same kVAR but a lower voltage rating. Common at medium and high voltage, usually ungrounded, with the neutral used for unbalance and blown-fuse detection.

Fixed, switched or automatic?

Fixed bank

Always connected. Correct for a base load that never goes away — a transformer's magnetising kVAR, or a motor that runs continuously. Size it to the minimum load so it can never overcorrect.

Automatic bank

Several steps switched in and out by a power factor controller. The right answer whenever load varies through the shift or the total exceeds roughly 100 kVAR. Aim for 4 to 8 steps so correction tracks the load closely.

Detuned (reactor) bank

A series reactor tunes the bank below the 5th harmonic. Required wherever variable-speed drives, rectifiers or UPS systems make up a large share of the load, otherwise the capacitors and the harmonic source can resonate.

How to use this calculator

  1. Pick Three-Phase or Single-Phase and the supply frequency.
  2. Choose how you know the load: real power in kW, apparent power in kVA, or a measured current in amps at the system voltage.
  3. Enter the Current Power Factor — the value on the utility bill or the power meter. Both 0.78 and 78 are accepted.
  4. Enter the Target Power Factor. Use the threshold in your tariff, typically 0.90 or 0.95.
  5. Press Calculate kVAR, then use the target slider in the results to see how the bank size responds before you commit to a rating.

What power factor correction actually saves

  • Penalty removal. Tariffs charge either a power factor penalty below a threshold or a demand charge on kVA. Both disappear once the measured power factor sits above the target.
  • Released capacity. Apparent power falls from \(P/PF_1\) to \(P/PF_2\). That freed kVA is real headroom on the transformer, switchgear and feeders — often enough to add load without an upgrade.
  • Lower losses. Line current falls in the ratio \(PF_1/PF_2\), and resistive losses fall with the square of that ratio. Correcting 0.75 to 0.95 cuts current by about 21% and \(I^2R\) losses by about 38%.
  • Better voltage. Less current means less voltage drop along long feeders, which helps motors start and run cooler.

Common mistakes when sizing a capacitor bank

  • Sizing from peak kW but running at part load. A fixed bank sized for the busiest hour will overcorrect at night. Size fixed banks to the minimum load and switch the rest.
  • Ignoring harmonics. Capacitors are a low-impedance path for harmonic current. With significant drive or rectifier load, specify a detuned bank instead of plain capacitors.
  • Bolting too much kVAR onto a motor. Exceeding the manufacturer's maximum kVAR for terminal correction can self-excite the motor on coast-down and produce damaging overvoltage.
  • Undersized conductors and protection. NEC 460.8 wants at least 135% of rated capacitor current in the conductor; protection is normally set at 135–165%.
  • Forgetting discharge time. Capacitors store energy after the supply is opened. Codes require the residual voltage to fall to a safe level within a set time — never re-energise or work on a bank before the discharge resistors have done their job.

Frequently asked questions

How do I calculate the kVAR of a capacitor bank?

Multiply the real power in kW by the difference of the tangents of the two power factor angles: \(Q_C = kW \times (\tan\phi_1 - \tan\phi_2)\). A 100 kW load at 0.75 corrected to 0.95 needs \(100 \times (0.8819 - 0.3287) = 55.3\) kVAR.

What target power factor should I choose?

Match the threshold in your tariff. 0.95 is the common commercial target; 0.98 is worth it where the utility bills on kVA demand. Correcting to 1.00 is rarely economic and increases the risk of a leading power factor at light load.

How many microfarads is 1 kVAR?

It depends entirely on voltage and frequency, because \(C = Q / (2\pi f V^2)\). At 480 V and 60 Hz, one kVAR in a delta bank is roughly 3.8 µF per phase; at 240 V and 60 Hz the same kVAR needs about 15 µF, four times as much, because capacitance scales with the inverse square of voltage.

Can a capacitor bank be too large?

Yes. Overcorrection pushes the power factor leading, raises system voltage, can trip generator reverse-VAR protection and is often penalised by the utility. If the load varies, use an automatic bank with several switched steps rather than one large fixed block.

Does correcting power factor reduce my kWh consumption?

Only slightly. Capacitors do not reduce the real energy the load consumes; the meter's kWh register barely moves. The savings come from the removed penalty or kVA demand charge, the released capacity, and a modest cut in resistive losses in your own cables.

Where should the capacitors be installed?

The closer to the inductive load, the more of the distribution system is relieved. Individual correction at the motor gives the biggest loss reduction; group correction at a motor control centre is a good compromise; bulk correction at the main switchboard fixes the utility bill but leaves the internal cables carrying the same reactive current.

Disclaimer: this calculator provides guideline figures for planning and study purposes. Final capacitor bank design, harmonic analysis, protection settings and conductor sizing must be reviewed by a qualified electrical engineer against the applicable local code and the equipment manufacturer's data.

引用此内容、页面或工具为:

"Capacitor Bank Sizing Calculator" 于 https://MiniWebtool.com/zh-cn/电容补偿柜容量计算器/,来自 MiniWebtool,https://MiniWebtool.com/

by miniwebtool team. Updated: 2026-08-19

电子工具:

常用工具:

职位查找器MAC地址查找彩票号码生成器随机信用卡生成器音频提取器英尺英寸转换为厘米网址提取器相对标准偏差计算器太阳、月亮与上升星座计算器 🌞🌙✨CAGR计算器随机扑克牌生成器SRT转为TXT工具比例计算器🎮 游戏灵敏度转换器MAC地址生成器🌡️ 体感温度计算器百分比折扣计算器按字母顺序排序太阳位置计算器音频分割器HEX计算器图片打码工具cpm计算器厘米到英尺和英寸转换器样本量计算器商和余数计算器毛利率计算器定期存款计算器斜边计算器Instagram用户ID查询VAT计算器农历转换器罗马数字转换器随机字符串生成器随机IMEI生成器FPS 转换器质数检查器合并视频调整视频速度kg到lbs转换器Facebook用户ID查询srt时间偏移磅转千克转换器血糖转换器位数计算器真心话大冒险生成器随机选择器随机化数字分数计算器视频转图片提取器🖱️ 点击计数器百分比到ppm转换器翻转视频One Rep Max (1RM) 计算器PSI 转 Bar 转换器对数计算器L-System分形生成器极坐标方程绘图器沸点计算器Log Base 10 计算器根式化简器为图片添加文字卧推计算器半衰期计算器kpa到psi转换器JPG 转 PDF随机扑克手牌生成器SHA256 哈希生成器月相计算器骰子滚轮合并 PDF指数计算器(高精度)🥧 饼图制作工具年度天数计算器 - 今天是今年的第几天Zalgo文本生成器卡方检验计算器百分比变化计算器磅到克转换器考拉兹猜想计算器📅 日期计算器螺栓扭矩计算器密码强度测试器MD5哈希生成器两点间距离计算器压缩 PDF月亮星座计算器开普勒第三定律计算器惯性矩计算器旋转视频黄金时刻和蓝调时刻计算器复数计算器年金现值计算器随机日期生成器拆分 PDF退休倒计时AI故事生成器t检验计算器csv转srt为视频添加水印图片分割器图着色计算器随机数字选择器WHOIS查询凯利公式计算器加价率计算器箱线图生成器跑步年龄分级计算器颜料调色计算器发音音标转换器散点图制作器毫米到英寸转换器随机超能力生成器密码生成器行数统计工具配色方案生成器SRT合并工具圆锥展开图模板生成器积分计算器迷宫生成器日历最简分数计算器📈 折线图制作工具泰勒级数计算器相关系数计算器💧 露点计算器不可见字符移除器逻辑门模拟器体脂百分比计算器反向文字椭圆周长计算器死链检查器闰年清单原根计算器数字提取器百分比增长率计算器随机坐标生成器ASCII码表三角函数绘图器多项式展开计算器平均值计算器排序数字百分比减少计算器随机问题生成器黄金分割计算器圆计算器百分比增加计算器英尺到米转换器镶嵌图案生成器随机域名生成器AI标点符号添加器DOY日历psi到kpa转换器YouTube Shorts收益计算器删除线文字生成器利率计算器在线记事本复利储蓄计算器我的幸运数字是什么楼梯计算器每个月的天数⏱️ 倒计时器双曲函数计算器圆台计算器标准偏差计算器 - 高精度电视安装高度计算器相同字母异序词生成器随机装备生成器随机锦标赛对阵生成器隐形文本生成器AI解梦Bar to PSI 转换器MAC 地址分析工具RC时间常数计算器VTT转txt转换器二选一问题生成器八进制计算器双重积分计算器反正切计算器天线长度计算器最小公倍数计算器移除标点符号在线工具角速度计算器随机RPG角色生成器3D曲面绘图器AI Token 计数器MP3循环器youtube收益估算器中位数计算器十六进制转CMYK转换器反函数计算器图片旋转器圆形面积计算器填字游戏制作器复利计算机自行车尺寸计算器视频压缩器24点游戏求解器与训练器Voronoi 图生成器⏱️ 在线秒表平方根计算器游戏昵称生成器团队名称生成器昵称生成器说唱艺名生成器乐队名称生成器奇幻名字生成器幸运饼干生成器绘画创意生成器日记提示生成器每日肯定语生成器赞美生成器搭讪台词生成器老爸笑话生成器随机笑话生成器随机冷知识生成器趣味问答题生成器猜词游戏单词生成器你画我猜词语生成器猜词游戏生成器破冰问题生成器我从来没有生成器AI感谢信生成器AI婚礼致辞生成器AI新闻稿生成器AI产品描述生成器AI视频脚本生成器AI YouTube标题和描述生成器AI Instagram标题生成器AI LinkedIn标题和简介生成器AI简历要点生成器AI求职信生成器AI说唱歌词生成器PDF展平工具PDF解锁-移除所有者密码PDF转文本提取器提取PDF页面PDF 字数统计PDF加密给PDF添加页码重新排序 PDF 页面删除 PDF 页面旋转 PDFPDF 转 JPGPT转PX转换器PX转REM转换器托拉转克转换器印度土地单位转换器微克转毫克转换器AI歌词生成器AI诗歌生成器AI翻译器AI文本摘要工具毫克到毫升转换器英里每小时转公里每小时转换器节到英里每小时转换器立方米转立方英尺立方英尺转立方码转换器平方英尺转平方米转换器平方米转平方英尺转换器盎司转毫升转换器毫升转盎司转换器加仑转升转换器升到加仑转换器千克到英石转换器英石转千克转换器英寸到毫米转换器英里转千米转换器千米转英里转换器华氏度到摄氏度转换器摄氏度转华氏度转换器背包尺寸计算器冲浪板体积计算器网球握把尺寸计算器头盔尺寸计算器手套尺寸计算器帽子尺码转换器单板滑雪板尺寸计算器双板滑雪板尺寸计算器速通分段计时器斯特伯福计分计算器飞镖残局计算器板球投球经济率计算器板球击球率计算器净得分率计算器KD比率计算器Elo 等级分计算器心率恢复计算器徒步时间计算器划船配速计算器FTP功率区间计算器Beep 测试计算器ACFT分数计算器Wilks & DOTS 计算器轮毂偏距计算器轮胎负荷指数与速度等级查询每英里成本计算器租赁买断计算器辛烷值混合计算器二冲程机油混合计算器发动机排量计算器沙发过门计算器木柴考得计算器空气净化器CADR计算器除湿机尺寸计算器吊扇尺寸计算器窗帘尺寸计算器地毯尺寸计算器挂画高度计算器电视尺寸计算器池塘容积和衬垫计算器泳池盐量计算器泳池容积计算器热水器尺寸计算器环氧树脂计算器栏杆立柱间距计算器踢脚线和装饰线条计算器壁板计算器露台木器染色剂计算器草籽计算器草皮计算器沥青计算器立方码计算器电线管填充率计算器串联并联电容计算器感抗计算器房间照明计算器勒克斯转流明计算器流明转瓦特转换器发电机功率计算器mah到wh转换器三相功率计算器kVA计算器安培转瓦特计算器瓦特转安培计算器串联电阻计算器摩擦力计算器斜面计算器机械效益计算器声速计算器波速计算器浮力计算器终端速度计算器德布罗意波长计算器光子能量计算器emc2计算器时间膨胀计算器逃逸速度计算器万有引力计算器比尔-朗伯定律计算器能斯特方程计算器渗透压计算器沸点升高计算器凝固点降低计算器百分比组成计算器当量浓度计算器质量摩尔浓度计算器pKa到Ka转换器亨德森-哈塞尔巴尔赫计算器理论产量计算器限制反应物计算器电子排布计算器交互式元素周期表AI教案生成器AI测验生成器引用生成器 (APA/MLA/Chicago)出勤率计算器AP分数计算器ACT分数计算器SAT分数计算器