PCB Via Current Calculator

Calculate how much current a PCB via can safely carry from its finished hole size, copper plating thickness, and allowed temperature rise, and find out how many vias you need in parallel for your target current. Uses the IPC-2221 ampacity model on the plated barrel cross-section, and also reports via resistance, voltage drop, power loss, and the real temperature rise at your operating current.

PCB Via Current Calculator
Quick examples — click to fill the form, then press Calculate:
The hole after plating — what you put in the drill file minus the plating.
IPC-6012 Class 2 is 20 µm average, Class 3 is 25 µm.
Used for resistance and loss. A blind or buried via spans less.
10 °C is the usual design default, 20 °C is aggressive.
What the net really carries — drives the via count.
Used for the final barrel temperature and copper resistance.
Both are always shown in the results, so you can see the spread.
⚡ Live estimate: per via 🟠 Copper area: 🔢 Vias needed:

Embed PCB Via Current Calculator Widget

PCB Via Current Calculator 정보

The PCB Via Current Calculator works out how much current one plated through-hole via can carry before its barrel heats up past the temperature rise you allow, and how many vias you need in parallel to move your actual load. It starts from the three things you control in the fabrication notes — finished hole diameter, copper plating thickness, and board thickness — and reports ampacity, barrel resistance, voltage drop, power loss, and the real temperature rise at your operating current.

How a Via Carries Current

A via is not a solid copper post. It is a drilled hole whose wall is electroplated with a thin layer of copper, so in cross-section the conductor is a ring, not a disc. The air in the middle carries nothing. That is why plating thickness matters so much: on a 0.3 mm hole, going from 20 µm to 25 µm of plating adds a quarter more copper and a fifth more current, while the drill size on the fabrication drawing does not change at all.

Step 1 — Copper cross-section of the barrel
$$A = \frac{\pi}{4}\left(D^2 - d^2\right) = \pi\,t\,(d + t)$$

where \(d\) is the finished hole diameter, \(t\) is the plating thickness, and \(D = d + 2t\) is the outer barrel diameter. Convert the result to square mils (multiply mm² by 1550) before using the IPC formula.

Step 2 — IPC-2221 current capacity
$$I = k \times \Delta T^{0.44} \times A^{0.725}$$

with \(k = 0.024\) for internal conductors and \(k = 0.048\) for external conductors, \(\Delta T\) in °C, and \(A\) in mil². The exponents are the important part: current scales with area to the power 0.725, so doubling the copper buys about 65% more current, and it scales with temperature rise to the power 0.44, so doubling the allowed rise buys only about 36% more.

Step 3 — Vias in parallel
$$n = \left\lceil \frac{I_{\text{target}}}{I_{\text{via}}} \right\rceil$$
Step 4 — Barrel resistance
$$R = \frac{\rho\,L}{A}\left[1 + \alpha\left(T - 20\right)\right]$$

with \(\rho = 1.72 \times 10^{-8}\) Ω·m for copper at 20 °C, \(\alpha = 0.00393\) per °C, \(L\) the board thickness the barrel spans, and \(T\) the barrel temperature. A typical 0.3 mm via through a 1.6 mm board lands near 1 mΩ.

Internal or External? Why Via Numbers Differ Between Calculators

IPC-2221 describes traces, not vias, and the standard offers two constants: one for conductors buried inside the stack-up and one for conductors on an outer layer with air above them. A via barrel is genuinely in between. It is surrounded by laminate, which argues for the internal constant, but it is hollow, air-filled, and tied to a pad on each surface, which argues for the external one. Different tools pick different sides, and that is the whole reason two reputable calculators can disagree by a factor of two on the same via.

This calculator always shows both. Use the conservative internal number for design reviews and anything safety-related, and treat the external number as an upper bound — the current at which the via is definitely not fine.

Typical Via Current Capacity

The table below assumes 25 µm (1 mil) of plating and a 10 °C rise — the most common combination in practice.

Finished holeCopper areaConservative (k = 0.024)Standard (k = 0.048)Typical use
0.15 mm (6 mil)13.7 mil²0.45 A0.90 AHDI microvia, fine-pitch BGA
0.20 mm (8 mil)17.4 mil²0.54 A1.07 ADense signal fanout
0.25 mm (10 mil)21.2 mil²0.62 A1.24 AStandard signal via
0.30 mm (12 mil)25.0 mil²0.70 A1.40 ADefault via, thermal arrays
0.40 mm (16 mil)32.5 mil²0.85 A1.70 ALight power rails
0.50 mm (20 mil)40.1 mil²0.99 A1.98 APower distribution
0.80 mm (31 mil)55.2 mil²1.26 A2.51 AConnector and TH component pins
1.00 mm (39 mil)65.2 mil²1.42 A2.85 AHigh-current terminals

Notice how flat that column is: a hole nearly seven times wider carries barely three times the current. Copper area grows only linearly with hole diameter for a fixed plating thickness, and ampacity then grows more slowly still. Several small vias beat one big one almost every time — and they are cheaper to drill.

How Much Plating Will You Actually Get?

SpecificationAverage copperMinimumNotes
IPC-6012 Class 120 µm18 µmConsumer, non-critical
IPC-6012 Class 220 µm18 µmMost commercial boards
IPC-6012 Class 325 µm20 µmHigh reliability, aerospace, medical
Typical quick-turn quote25 µm (1 mil)18 µmWhat most prototype houses ship
Heavy copper process50–75 µmExtra cost, longer lead time

If you do not know what your fabricator supplies, enter 20 µm. It is the floor for Class 2 and it keeps the answer on the safe side of whatever you actually receive.

Design Tips for High-Current Vias

🔢 Many small beats one big

Four 0.3 mm vias carry far more than one 0.6 mm via, cost the same to drill, and keep the plane cut-outs small.

📏 Spread them out

Vias packed tightly heat each other. A 1.0–1.2 mm pitch lets each barrel dump heat into the surrounding copper.

🧲 Watch the return path

Every power via needs a matching ground via nearby, or the return current takes a long loop and the inductance ruins your decoupling.

🌡️ Vias are heat sinks too

An array under a regulator or LED pad conducts heat into an inner plane. The same copper does both jobs.

⚖️ Assume uneven sharing

Parallel vias share current only if the paths are symmetric. Adding 20–50% more vias than the maths demands is normal.

🕳️ Mind the aspect ratio

Board thickness divided by drill diameter above roughly 10:1 makes even plating hard, so thin plating in deep holes is a real risk.

How to Use This Calculator

  1. Enter the finished hole diameter — the hole after plating, in mm or mil.
  2. Enter the copper plating thickness in µm, mil, or ounces. 25 µm is the usual default.
  3. Enter the board thickness the via passes through; a blind or buried via spans less than the full stack.
  4. Set the allowed temperature rise (10 °C is standard) and your target current.
  5. Pick the IPC-2221 model, then click Calculate Via Current.
  6. Read the ampacity of one via, the number of vias needed, and the resistance, drop, and power loss.

Limitations You Should Know About

  • IPC-2221 is a trace standard. Applying it to a via barrel is standard industry practice but it is an approximation, not a measurement.
  • Steady-state DC only. Short pulses can exceed these numbers by a wide margin; high-frequency current crowds toward the barrel wall surface.
  • No neighbouring-copper credit. A via dropping into a large plane runs cooler than this predicts; a via in an isolated island runs hotter.
  • Plating varies. Real plating is thinner in the middle of a deep hole than at the ends. Use the minimum your fabricator guarantees, not the average.
  • Not a substitute for thermal simulation on anything dense, high-power, or safety-critical.

One number worth keeping in perspective: a single 0.3 mm via through a 1.6 mm board is only about 1 mΩ, which is negligible next to the trace it connects. Via resistance starts to matter on high-current rails and switching-regulator return paths, where several milliohms in series add up — and it always matters for the power lost as heat, which is what raises the barrel temperature in the first place.

Frequently Asked Questions

How much current can a PCB via carry?

It depends almost entirely on how much copper is in the barrel wall. A standard 0.3 mm finished hole with 25 µm of plating has about 40 mil² of copper, which carries roughly 1 A at a 10 °C rise on the conservative IPC-2221 internal model, or about 1.9 A on the external model. A 0.5 mm hole with the same plating carries roughly 1.5 to 3 A. Doubling the hole size does not double the current, because ampacity scales with cross-section to the power 0.725.

What is the formula for via current capacity?

The via barrel is treated as a conductor with an annular cross-section, so A = π t (d + t), where d is the finished hole diameter and t is the plating thickness. That area, in mil², goes into the IPC-2221 ampacity formula I = k ΔT0.44 A0.725, with k = 0.024 for internal conductors and k = 0.048 for external conductors.

Should I use the internal or external IPC-2221 constant for a via?

IPC-2221 was written for traces, not vias, so neither constant is exact. The internal constant k = 0.024 is the conservative choice and is what most design reviews expect, because the barrel is surrounded by laminate. Some calculators use the external constant k = 0.048 on the grounds that the hollow barrel is cooled by air and by the pads at both ends. This calculator shows both so you can see the spread and decide how much margin you want.

How many vias do I need for 5 amps?

Divide the target current by the capacity of one via and round up. With 0.3 mm vias plated to 25 µm at a 10 °C rise, one via carries about 1 A on the conservative model, so 5 A needs at least 5 vias, and 6 to 8 is a safer choice once uneven current sharing is allowed for. Larger 0.5 mm vias cut that to 3 or 4.

How thick is via plating?

IPC-6012 Class 2 requires an average of 20 µm of copper in the hole wall with an 18 µm minimum, and Class 3 requires an average of 25 µm with a 20 µm minimum. Most fabricators quote 25 µm, which is 1 mil or about 0.7 oz. Heavy copper processes can reach 50 to 75 µm at extra cost. If you do not know what your fabricator gives you, entering 20 µm keeps the answer on the safe side.

Do thermal vias carry current or heat?

Both, and the same geometry drives each. A via array under a power pad conducts heat into an inner plane or the bottom copper, and the copper barrel that carries that heat also carries current. Thermal via arrays are usually 0.3 mm vias on a 1.0 to 1.2 mm grid, so the current capacity this calculator reports for one via, multiplied by the number of vias in the array, tells you how much current the same array can pass.

Related Calculations

Size the copper on the layer as well as through it with the PCB Trace Width Calculator, check the loss along the run with the Voltage Drop Calculator, and work out conductor resistance directly with the Wire Resistance Calculator.

이 콘텐츠, 페이지 또는 도구를 다음과 같이 인용하세요:

"PCB Via Current Calculator" - https://MiniWebtool.com/ko/pcb-비아-전류-계산기/에서 MiniWebtool 인용, https://MiniWebtool.com/

by miniwebtool team. Updated: August 20, 2026

전자공학 도구:

주요 도구:

인스타그램 사용자 ID 조회분수 계산기애너그램 생성기방어율 계산기내 행운의 숫자는?평균 계산기상대 표준 편차 계산기랜덤 이름 생성기👙 브라 사이즈 계산기파운드→킬로그램 변환기16진수에서 10진수로 변환기주사위 굴리기시험관 출산 예정일 계산기OPS 계산기🎮 게임 감도 변환기무작위 초능력 생성기러닝 페이스 계산기공백 제거16진수 변환기토크 변환기 (Nm, ft-lb, kgf-cm)kg에서 파운드로 변환기10진수를 16진수로 변환cm에서 피트와 인치로 변환기소인수분해 계산기사랑 궁합 계산기피트 인치 센티미터 변환기WAR 계산기무작위 토너먼트 대진표 생성기로마 숫자 변환기벤치 프레스 계산기요일 계산기💧 이슬점 계산기무작위 날짜 생성기이미지 분할기긴 나눗셈 계산기이닝당 적중률(WHIP) 계산기수면 계산기CAGR 계산기야구 배팅 계산기무작위 문자열 생성기FIP 계산기랜덤 영어 단어 생성기랜덤 생일 생성기줄 바꿈 제거랜덤 동물 생성기기대 수명 계산기명언 검색기 (영어)근무 시간 계산기YouTube 채널 통계랜덤 그룹 생성기월경주기 계산기ppm에서 퍼센트 변환기복리 계산기랜덤 토론 주제 생성기기울기 및 경사 계산기분수에서 소수로 계산기Watts to Amps CalculatorFPS 변환기연비 계산기면적 계산기자전거 사이즈 계산기속도 변환기mAh to Wh 변환기최대 공약수 계산기암페어에서 와트 계산기야구 장타율 계산기소수 검사기원형 면적 계산기📅 날짜 계산기금리 계산기분수 백분율 변환기비례식 계산기어린이 BMI 백분위수 계산기연봉 인상 계산기퍼센트에서 PPM으로 변환기잘고 텍스트 생성기주차 계산기변화율 계산기연중 일수 계산기 - 오늘은 올해의 몇 번째 날인가요HEX 계산기키 백분위수 계산기영업 마진 계산기바코드 생성기랜덤 식사 생성기타이어 크기 계산기형량 감경 계산기센티미터에서 인치로 변환기암호화폐 레버리지 계산기몫과 나머지 계산기인치에서 센티미터으로 변환기출루율 계산기작은 텍스트 생성기 ⁽ᶜᵒᵖʸ ⁿ ᵖᵃˢᵗᵉ⁾비디오 이미지 추출기출산 예정일 계산기⏱️ 시간 계산기혈당 변환기임신 날짜 계산기시저 암호 도구자동차 대출 계산기중앙값 계산기임대 수익률 계산기확률 계산기kVA 계산기PSI에서 bar로 변환기두 날짜 사이 일수 계산기출생 요일 계산기태양, 달 & 상승궁 계산기 🌞🌙✨kPa에서 psi로 변환기영업일 계산기거꾸로 텍스트 생성기모스 부호 생성기🎰 가챠 천장 계산기반지 사이즈 변환기십자수 실 계산기최대 심박수 계산기피타고라스 정리 계산기홈런 타율 계산기콜라츠 추측 계산기예쁜 글씨 생성기페이스북 사용자 ID 조회백분율 증가 계산기시간 지연 계산기임신 체중 증가 계산기간헐적 단식 계산기십진수에서 이진수로 변환기다중 분수 계산기랜덤 국가 생성기백분율 성장 계산기MAC 주소 조회단어 찾기 퍼즐 생성기일할 계산 월세 계산기번호 정렬16진수에서 이진법 변환기ANC 계산기오디오 추출기초과 근무 수당 계산기역함수 계산기영업 이익률 계산기암산 트레이너음력 양력 변환기YouTube 쇼츠 수익화 계산기🌬️ 체감 온도 계산기속도 계산기자녀 키 예측기퍼센트 감소 계산기헌혈 시간 계산기mcg에서 mg로 변환기마틴게일 전략 계산기반올림 계산기동영상 병합배당 수익률 계산기칵테일 ABV 계산기이진 계산기이진수를 십진수로 변환1RM (1회 최대 반복) 계산기TDEE 계산기목표 심박수 계산기볼링 점수 계산기임대료 인상 계산기자동차 감가상각 계산기직각삼각형 계산기태양 위치 계산기무작위 포커 핸드 생성기옥탄가 혼합 계산기정기 예금 계산기출석률 계산기텍스트 찾기 및 바꾸기호 길이 계산기랜덤 물품 생성기반전 텍스트HTML에서 텍스트 변환기공학용 계산기타원 둘레 계산기손절 및 익절 계산기취소선 텍스트 생성기가위바위보 생성기세제 사용량 계산기이름 번호 계산기n항 계산기백분율 할인 계산기소수 분수 변환기자전거 기어비 계산기급여 변환 계산기문자열 길이 얻기한 달에 일빗변 계산기스도쿠 생성기 및 풀이기즉시 연금 계산기랜덤 수학 문제 생성기미로 생성기색상 조합 생성기전선 게이지 계산기🖱️ 클릭 카운터SAT 점수 계산기낮잠 계산기변동 계수 계산기시간 지속 계산기신발 사이즈 변환기연분수 계산기중복 줄 제거게이머태그 생성기팀 이름 생성기닉네임 생성기랩 이름 생성기밴드 이름 생성기판타지 이름 생성기포춘 쿠키 생성기그림 아이디어 생성기저널 프롬프트 생성기데일리 확언 생성기칭찬 생성기작업 멘트 생성기아재 개그 생성기랜덤 농담 생성기랜덤 사실 생성기트리비아 문제 생성기행맨 단어 생성기픽셔너리 단어 생성기제스처 게임 생성기아이스브레이커 질문 생성기네버 해브 아이 에버 생성기밸런스 게임 생성기랜덤 질문 생성기AI 꿈 해몽AI 감사 편지 생성기AI 결혼식 축사 생성기AI 보도자료 생성기AI 제품 설명 생성기AI 영상 스크립트 생성기AI 유튜브 제목 및 설명 생성기AI 인스타그램 캡션 생성기AI LinkedIn 헤드라인 및 소개 생성기AI 이력서 불릿 생성기AI 커버레터 생성기AI 랩 가사 생성기PDF 평면화 도구PDF 잠금 해제 (소유자 암호 제거)PDF 텍스트 추출기PDF 페이지 추출기PDF 단어 세기PDF 보호PDF에 페이지 번호 추가PDF 페이지 순서 변경PDF 페이지 삭제PDF 회전JPG를 PDF로 변환PDF를 JPG로 변환PDF 압축PDF 분할PDF 병합PT에서 PX로 변환기PX에서 REM 변환기톨라에서 그램 변환기인도 토지 단위 변환기AI 노래 가사 생성기AI 시 생성기AI 스토리 생성기AI 번역기AI 텍스트 요약기mg에서 mL 변환기MPH에서 KMH 변환기노트-마일 변환기세제곱미터에서 세제곱피트세제곱피트에서 세제곱야드 변환기제곱피트에서 제곱미터 변환기제곱미터에서 제곱피트 변환기온스를 mL로 변환기mL를 온스로 변환기갤런에서 리터 변환기리터에서 갤런 변환기킬로그램 스톤 변환기스톤 킬로그램 변환기인치에서 밀리미터로 변환기밀리미터에서 인치로 변환기마일 킬로미터 변환기킬로미터-마일 변환기화씨-섭씨 변환기섭씨 화씨 변환기배낭 크기 계산기서핑보드 부피 계산기테니스 그립 사이즈 계산기헬멧 사이즈 계산기장갑 사이즈 계산기모자 사이즈 변환기스노보드 사이즈 계산기스키 사이즈 계산기스피드런 스플릿 타이머스테이블포드 계산기다트 체크아웃 계산기볼링 이코노미 계산기타격 스트라이크 레이트 계산기네트 런 레이트 계산기K/D 비율 계산기Elo 레이팅 계산기심박수 회복 계산기하이킹 시간 계산기로잉 페이스 계산기달리기 연령 등급 계산기FTP 및 파워 존 계산기Beep 테스트 계산기ACFT 점수 계산기Wilks & DOTS 계산기휠 오프셋 계산기타이어 하중 지수 및 속도 등급 조회마일당 비용 계산기리스 바이아웃 계산기2행정 오일 혼합 계산기엔진 배기량 계산기소파 문 통과 계산기장작 코드 계산기공기청정기 CADR 계산기제습기 크기 계산기천장 선풍기 크기 계산기커튼 크기 계산기러그 크기 계산기그림 거는 높이 계산기TV 설치 높이 계산기TV 크기 계산기연못 용적 및 라이너 계산기수영장 소금 계산기수영장 부피 계산기온수기 크기 계산기에폭시 레진 계산기난간동자 간격 계산기걸레받이 및 트림 계산기사이딩 계산기데크 스테인 계산기잔디 씨앗 계산기잔디 계산기아스팔트 계산기세제곱야드 계산기안테나 길이 계산기전선관 충전율 계산기직렬/병렬 커패시터 계산기유도 리액턴스 계산기방 조명 계산기럭스 루멘 계산기루멘 와트 변환기발전기 크기 계산기3상 전력 계산기직렬 저항 계산기마찰 계산기경사면 계산기기계적 이득 계산기음속 계산기파동 속도 계산기부력 계산기종단 속도 계산기드브로이 파장 계산기광자 에너지 계산기E=mc² 계산기케플러 제3법칙 계산기탈출 속도 계산기만유인력 계산기비어 람베르트 법칙 계산기네른스트 방정식 계산기삼투압 계산기끓는점 오름 계산기어는점 내림 계산기백분율 조성 계산기노르말 농도 계산기몰랄농도 계산기pKa Ka 변환기헨더슨 하셀바흐 계산기이론 수율 계산기한계 반응물 계산기전자 배치 계산기인터랙티브 주기율표AI 수업 지도안 생성기AI 퀴즈 생성기인용 생성기 (APA/MLA/Chicago)AP 점수 계산기ACT 점수 계산기유튜브 수익 추정기무작위 RPG 캐릭터 생성기